Memphis Mechanical
Services, Inc. offers customized preventive maintenance programs designed to suit each client's specific needs. Geographic location, type of facility, usage, and budget are all factors in setting up a customized program.
Memphis Mechanical has developed individualized preventive maintenance programs for supermarkets, convenience stores, lab environments and retail establishments. Let us customize an agreement, which meets your individual requirements.

|
Maintenance - Frequently Asked Questions |
Is
preventive maintenance a necessity?
Preventive
Maintenance is essential to the proper functioning of
Refrigeration and HVAC equipment. If preventive maintenance
is not performed regularly or if it is done haphazardly, the
equipment will require extensive and costly repairs at a
later date. This is not just a case of "pay me now or pay me
later." It is a case of "pay me now or pay me considerably
more, later," and loose reliability in the process. The
following will explain the specific cause and affect between
neglected maintenance tasks, the failures that result, and
why preventive maintenance is necessary.
Preventive
maintenance of Refrigeration and HVAC equipment, of the
types typically installed in retail stores, consists of
several regular inspections each year. During these
inspections, proper operation of the equipment is checked
and verified, electrical relays and contactors are
inspected, operation of safety controls is verified, air
filters are replaced, drive belts are inspected and replaced
as required, bearings are lubricated, and heat transfer
surfaces are cleaned. In addition, if the unit utilizes
combustion of fossil fuels for heating, the burners will be
serviced and cleaned during at least one inspection. All
mechanical equipment is designed to operate within certain
limits. A passenger car, for example is designed to carry
the weight of four occupants plus luggage, perhaps 1200
pounds. If you were to load that vehicle with 5000 pounds of
weight, catastrophic damage would result. Similarly, if you
operated a personal computer in a closed box for a length of
time, it would burn up. The damage in both cases is a direct
result of the equipment being required to operate under
conditions that are far beyond the operating limits set by
its designer and builder. Similarly, Refrigeration and HVAC
equipment also has certain design limits, and if not
properly maintained, the equipment will exceed its design
limitations with the result being catastrophic failure.
Why must we clean condenser coils?
Equipment is designed to operate between certain outdoor temperature limits. Cooling and condensing of the refrigerant vapor is designed to occur with a particular volume of air flowing through the condenser at a maximum outdoor ambient temperature. (Usually 115ェ) If the finned surfaces of the outdoor coils are fouled with dirt, the ability of these coils to transfer heat is reduced and the airflow through the condenser coil is reduced. When the ability to transfer heat is reduced, the operating temperatures and pressures of the unit increase. If the unit's ability to dissipate heat is reduced, a unit, which may have been designed to operate at ambient temperatures of 115ェ or more, may stop operating at an outdoor temperature of 90ェ. Due to the reduced heat transfer capability, the operating temperatures and pressures within the unit exceed the manufacturer's safe limit and the unit shuts down. If the unit does not exceed the manufacturer's limits by enough to require a shut down, it will continue to run at reduced capacity and efficiency, and at an increased rate of wear due to the increased work load.
Why inspect
relays and contactors?
Electrical relays are designed to open and close a predetermined number of times with a particular current load, before the contact points are damaged to the degree that the relay requires replacement. If more than the design current is passed through this relay due to a motor working too hard, or low voltage conditions, the contact points overheat and become damaged. If the electrical contacts in a contactor (large relay) begin to get pitted, and the contactor is not replaced, eventually the compressor motor or the fan motor controlled by the contactor will burn up and require replacement. Once again, if we exceed the design limitations of the device, or its anticipated life span, additional damage is caused.
Why must we
lubricate bearings and rotating components?
Bearings and other rotating parts are designed to have a useful life span of hundreds of thousands of hours. However, this projected useful life is based upon the assumption that the bearings will be lubricated at appropriate intervals and that the bearing surfaces will not be overloaded due to vibration from defective drive belts or dirty blower wheels. If bearings are not lubricated regularly, they will overheat and seize. When this occurs, the bearings fall apart, and the blower wheel, shaft, and housing are destroyed. This is a prime example of a situation where inexpensive maintenance was neglected with catastrophic results.
Why must we
check the refrigerant charge on a regular basis?
Sufficiency of refrigerant charge must be checked on a regular basis. A unit operating with an insufficient refrigerant charge can ruin its compressor via two scenarios. The unit icing up due to a low-pressure condition causes the first type of failure, causing the compressor to fail due to liquid slugging, as described before. The second type of failure is due to the fact that the compressor requires a certain quantity of cool refrigerant vapor to cool its motor windings. If the refrigerant charge is not sufficient, the motor within the compressor will overheat and burn up.
The scenarios described all cause damage to occur slowly, over a period of time, usually without being noticed until catastrophic failure has occurred. Compressors and indoor blower motors should last for 10 years if their design limitations are not exceeded due to poor maintenance or failure of another component. Without proper maintenance, a typical rooftop unit can ruin its compressor within 1.5 years and a typical refrigeration system within days or even hours.
Regularly scheduled preventive maintenance properly performed, in addition to lowering overall annual Refrigeration and HVAC service costs, and reducing the number of emergency calls due to catastrophic failures, will also result in lower utility costs. Properly maintained equipment operates more efficiently.
Why must we replace air filters?
Air conditioning equipment is designed to operate with a specific quantity of air passing over its indoor coil surface, typically between 300 and 400 cubic feet of air/per minute/ per ton of air conditioning. When air filters are not replaced at regular intervals, they clog and become coated with dirt. Similarly, the indoor coils get coated with dirt. This dirt blocks a portion of the air flow, which means that the amount of air passing through the unit drops below the 300 cubic feet of air/ per ton design limit, leading to catastrophic failures.
In the cooling mode, if there is not enough air over the indoor coil, the coil temperature drops. When the coil temperature drops below the freezing point, ice forms on the coil, which further reduces the airflow, this in turn further reduces the coil temperature. The compressor within the unit is a pump, which is designed to pump a vapor. As the airflow through the indoor coil drops, there isn't enough heat being removed from the air passing over the coil to vaporize the liquid refrigerant inside the tubes, which make up the coil. Therefore, instead of receiving a vapor, the compressor receives liquid refrigerant. This is commonly known as "liquid slugging". The effect of "liquid slugging" is similar to the effect of pouring a liquid into the cylinders of an operating automobile engine. Because liquids are not compressible, the pressure within the cylinders exceeds the design limit of the cylinder, and the valves, connecting rods, pistons, or other internal components are destroyed. The units start out requiring that its filters be replaced. Now it needs a new compressor.
In the heating mode, low airflow leads to overheating of the heat exchanger. This tubular steel assembly separates the air being circulated from the flame and the products of combustion. The heat exchanger is designed to operate at a temperature between 120ェ and 200ェ. If the operating temperature exceeds theses temperatures, the heat exchanger oxidizes quickly and its useful life is reduced below the anticipated normal life-span, or the heat exchanger cracks and breaks. In either case, it makes far more sense to replace air filters regularly than to replace a heat exchanger costing thousands of dollars.
Why must we replace drive belts?
Loose or broken drive belts cause the same problems that dirty filters cause. This is due to the fact that they also cause the airflow through the equipment to be reduced below design limits. In addition, loose drive belts slip on the pulleys they are meant to drive. This wears the groove in the pulley so that when the belt is finally replaced, the new belt is ruined in a short period of time by the worn pulleys. Once again replace the $15.00 belt on a regular basis or spend $300.00 replacing pulleys.
|
|